1.
Pacing Clin Electrophysiol ; 47(5): 635-641, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38552167

RESUMO

BACKGROUND: The stretching of the lead caused by somatic growth may lead to complications (dislodgement, fracture, failure) of transvenous leads implanted in pediatric patients. Atrial loop and absorbable ligatures may prevent it. Periodical lead advancement with lead pushing from the pocket may be an option to growth-induced stretching. Our aim was to analyze retrospectively the outcome of periodical transvenous lead advancement in children with pacemaker (PM). METHODS: A procedure of lead advancement was performed in patients with a single-chamber PM implanted for isolated congenital complete atrioventricular block or sinus node dysfunction with growth-induced lead straightening/stretching. The PM pocket was opened, the lead was released from subcutaneous adherences and was gently advanced to shape again a loop/semi-loop in the atrium without dislodging the tip. Lead data (threshold, sensing, impedance) were compared before and after the procedure. Data are described as median (25th-75th centiles). RESULTS: 14 patients with 13 VVIR and 1 AAIR PM implanted at 6.8 (5.9-8.0) years of age, 23 (19-26) kg, 118 (108-124) cm, underwent 30 advancement procedures, 1.5 (1.0-2.3) per patient, during follow-up [45 (35-63) months]. Delta between procedures was: 18 (14-25) months, 11 (7-13) cm, 6 (4-9) kg; 90% of leads were successfully advanced without complications. Three unsuccessful procedures occurred with longer times [30 (14-37) months]. Electrical lead parameters did not show significant differences pre-/post-procedures. CONCLUSION: the advancement of transvenous leads in children seems safe and effective. This procedure may be another possible choice to preserve transvenous lead position and function until growth has completed.


Assuntos
Marca-Passo Artificial , Humanos , Masculino , Feminino , Estudos Retrospectivos , Criança , Pré-Escolar , Eletrodos Implantados , Bloqueio Atrioventricular/terapia , Síndrome do Nó Sinusal/terapia
2.
Europace ; 25(4): 1482-1490, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36794445

RESUMO

AIMS: In congenitally corrected transposition of the great arteries (CCTGA) the right ventricle (RV) is systemic. Atrioventricular block (AVB) and systolic dysfunction are frequently observed. Permanent pacing of the subpulmonary left ventricle (LV) may worsen RV dysfunction. The aim of this study was to seek out if LV conduction system pacing (LVCSP) guided by three-dimensional-electroanatomic mapping systems (3D-EAMs) can preserve RV systolic function in paediatric CCTGA patients with AVB. METHODS AND RESULTS: Retrospective analysis of CCTGA patients who underwent 3D-EAM-guided LVCSP. Three-dimensional-pacing map guided lead implantation towards septal sites with narrower paced QRS. Electrocardiograms (ECGs), echocardiograms, and lead parameters (threshold, sensing, and impedance) were compared at baseline (pre-implantation) and at 1-year follow-up. Right ventricle function was evaluated by 3D ejection fraction (EF), fractional area change (FAC), RV global longitudinal strain (GLS). Data are reported as median (25th-75th centiles). Seven CCTGA patients aged 15 (9-17) years, with complete/advanced AVB (4 with prior epicardial pacing), underwent 3D-guided LVCSP (5 DDD, 2 VVIR). Baseline echocardiographic parameters were impaired in most patients. No acute/chronic complications occurred. Ventricular pacing was >90%. At 1-year follow-up QRS duration showed no significant changes compared with baseline; however, QRS duration shortened in comparison with prior epicardial pacing. Lead parameters remained acceptable despite ventricular threshold increased. Systemic RV function was preserved: FAC and GLS improved significantly, and all patients showed normal RV EF (>45%). CONCLUSION: Three-dimensional-EAM-guided LVCSP preserved RV systolic function in paediatric patients with CCTGA and AVB after short-term follow-up.


Assuntos
Bloqueio Atrioventricular , Transposição dos Grandes Vasos , Humanos , Criança , Transposição das Grandes Artérias Corrigida Congenitamente/complicações , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/terapia , Estudos Retrospectivos , Sistema de Condução Cardíaco , Ventrículos do Coração/diagnóstico por imagem , Estimulação Cardíaca Artificial/métodos
3.
Cardiol Young ; 33(5): 760-765, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35673795

RESUMO

BACKGROUND: Permanent pacing in children with isolated congenital complete atrioventricular block may cause left ventricular dysfunction. To prevent it, alternative pacing sites have been proposed: left ventricular epicardial or selective right ventricular endocardial pacing. AIMS: To compare the functional outcome (left ventricular systolic function and synchrony) in paediatric patients with congenital complete atrioventricular block and left ventricular apical epicardial or right ventricular transvenous mid-septal pacing. METHODS: Retrospective study. Epicardial leads were implanted by standard surgical technique, transvenous leads by 3D electroanatomic mapping systems. 3D mapping acquired 3D right ventricular local pacing map and defined the narrowest paced QRS site. 3D mapping guided screw-in bipolar leads on that ventricular site. Electrocardiogram (ECG) (QRS duration) and echocardiographic data (synchrony: interventricular mechanical delay, septal to posterior wall motion delay, systolic dyssynchrony index; contractility: global longitudinal strain, ejection fraction) were recorded. Data are reported as median [interquartile ranges]. p < 0.05 was significant. RESULTS: There were 19 transvenous systems (age 8.8 [6-14] years; right ventricular mid-septum) and 17 epicardial systems (0.04 [0.001-0.6] years; left ventricular apex). Post-implantation QRS significantly widened either in endocardial or in epicardial patients. Most patients reached 4-year follow-up. One-year and 4-year ejection fraction and global longitudinal strain were mostly within normal limits and did not show significant differences between the two groups and between the same endocardial/epicardial group. Synchrony parameters were within normal limits in the two groups. CONCLUSIONS: Left ventricular apical epicardial pacing and 3D mapping-guided right ventricular mid-septal pacing preserved left ventricular contractility and synchrony in children and adolescents with congenital complete atrioventricular block at short-/mid-term follow-up, without relevant significant differences between the two groups.


Assuntos
Bloqueio Atrioventricular , Estimulação Cardíaca Artificial , Adolescente , Humanos , Criança , Bloqueio Atrioventricular/terapia , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda
4.
J Cardiovasc Dev Dis ; 9(2)2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-35200687

RESUMO

BACKGROUND: Pediatric patients with cardiomyopathies are at risk of malignant arrhythmias and sudden cardiac death (SCD). An ICD may prevent SCD. The aim of this study was to evaluate ICD implantation outcomes, and to compare transvenous and subcutaneous ICDs (S-ICDs) implanted in pediatric patients with cardiomyopathies. METHODS: The study is single center and retrospective, and includes pediatric patients with cardiomyopathies who required ICD implantation (2010-2021). Outcomes were recorded for appropriate/inappropriate ICD therapy and surgical complications. Transvenous ICD and S-ICD were compared. Data are presented as median values (25th-75th centiles). RESULTS: Forty-four patients with cardiomyopathies (hypertrophic 39%, arrhythmogenic 32%, dilated 27%, and restrictive 2%) underwent transvenous (52%) and S-ICD (48%) implantation at 14 (12-17) years of age, mostly for primary prevention (73%). The follow-up period was 29 (14-60) months. Appropriate ICD therapies were delivered in 25% of patients, without defibrillation failures. Lower age at implantation and secondary prevention were significant risk factors for malignant ventricular arrhythmias that required appropriate ICD therapies. ICD-related complications were surgical complications (18%) and inappropriate shocks (7%). No significant differences in outcomes were recorded, either when comparing transvenous and S-ICD or comparing the different cardiomyopathies. CONCLUSIONS: In pediatric patients with cardiomyopathy, ICD therapy is effective, with a low rate of inappropriate shocks. Neither ICD type (transvenous and S-ICDs) nor the cardiomyopathies subgroup revealed divergent outcomes.

5.
Heart Rhythm ; 18(3): 434-442, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33307214

RESUMO

BACKGROUND: Nonfluoroscopic 3-dimensional (3D) electroanatomic mapping systems (EAMs) have been developed to guide cardiac catheter navigation and reduce fluoroscopy. Selective right ventricular (RV) septal pacing could prevent pacing-induced left ventricular (LV) dysfunction. OBJECTIVE: The purpose of this study was to determine whether EAM-guided selective RV septal pacing preserves LV contractility/synchrony in pediatric patients with complete atrioventricular block (CAVB) and no other congenital heart defects. METHODS: Prospective analysis of children/adolescents who underwent EAM-guided selective RV pacing was performed. A 3D pacing map guided ventricular lead implantation at septal sites with narrow paced QRS. Serial echocardiograms were obtained after pacemaker implantation to monitor for function (volumes, ejection fraction [EF], global longitudinal/circumferential strain) and synchrony (interventricular mechanical delay, septal to posterior wall motion delay, systolic dyssynchrony index). Data are reported as median (25th-75th percentile). RESULTS: Thirty-two CAVB patients (age 9.8 [7.0-14.0] years; 11 with a previous pacing system) underwent selective RV septal pacing (13 DDD, 19 VVIR pacemaker; midseptum 22, parahisian 7, RV outflow tract 3) with narrow paced QRS (110 [100-120] ms) and low radiation exposure. Follow-up over 24 (5-33) months showed preserved LV function and synchrony, without significant differences between pacing sites (midseptum-parahisian) and mode (VVIR-DDD). EF decreased after implantation in patients without previous pacing, although values were mainly within normal limits. Three parahisian patients underwent early lead repositioning. CONCLUSION: EAM-guided selective RV septal pacing is a feasible technique associated with preserved LV systolic function and synchrony and low radiation exposure in pediatric patients with CAVB.


Assuntos
Bloqueio Atrioventricular/diagnóstico , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/diagnóstico por imagem , Imageamento Tridimensional , Marca-Passo Artificial , Volume Sistólico/fisiologia , Adolescente , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Criança , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Sístole , Resultado do Tratamento , Função Ventricular Esquerda , Septo Interventricular
6.
Pacing Clin Electrophysiol ; 43(6): 535-541, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32233121

RESUMO

BACKGROUND: Small retrospective studies reported that left ventricular (LV) pacing is likely to preserve LV function in children with isolated congenital complete atrioventricular block (CCAVB). The aim of this study was to prospectively evaluate LV contractility and synchrony in a cohort of neonates/infants at pacemaker implantation and follow-up. METHODS: Patients with CCAVB who underwent LV pacing were evaluated with electrocardiogram and echocardiogram in a single-center, prospective study. Data were collected at implantation, at 1-month and every year of follow-up, up to 5 years. LV ventricular dimensions (diameters and volumes), systolic function (ejection fraction [EF] and global longitudinal strain [GLS]), and synchrony were evaluated. Data are reported as median (25th-75th centiles). RESULTS: Twenty consecutive patients with CCAVB underwent pacemaker implantation (12 single-chamber pacemaker [VVIR] and eight dual-chamber pacemaker [DDD]) with epicardial leads: 17 on the LV apex and three on the free wall. Age at implantation was 0.3 months (1 day-4.5 months). Patients showed good clinical status, normal LV dimensions, preserved systolic function, and synchrony at 60 (30-60) months follow-up. EF increased to normal values in patients with preimplantation EF <50%. Presence of antibodies and pacing mode (DDD vs VVIR) had no impact on the outcome. CONCLUSIONS: LV pacing preserved LV systolic function and synchrony in neonates and infants with CCAVB at 5-year follow-up. LV EF improved in patients with low preimplantation EF. Pacing mode or the presence of autoantibodies did not demonstrated an impact on LV contractility and synchrony.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia , Eletrocardiografia , Bloqueio Cardíaco/congênito , Sístole/fisiologia , Função Ventricular Esquerda/fisiologia , Pré-Escolar , Feminino , Seguimentos , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Humanos , Recém-Nascido , Masculino , Estudos Prospectivos , Fatores de Tempo
7.
Pacing Clin Electrophysiol ; 41(9): 1204-1211, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29989185

RESUMO

BACKGROUND: Alternative right ventricular (RV) sites (RVAPS) have been proposed to prevent or reduce RV pacing-induced left-ventricular (LV) dysfunction. Nonfluoroscopic 3D electroanatomic mapping systems (EAM) have been developed to guide cardiac catheter navigation and reduce fluoroscopy during electrophysiological procedures or pacemaker implantations. AIM: The aim of the study was to compare the results of EAM-guided permanent pacemaker implantation aiming at RVAPS with conventional fluoroscopic-guided implantation in RV apex (RVA) in children and adolescents. METHODS: A prospective, randomized analysis was performed on children/adolescents with complete atrioventricular block (CAVB) who underwent EAM-guided pacemaker and transvenous leads implantation into RVAPS (EAM-RVAPS) or conventional, fluoroscopic-guided implantation into RV apex (RVA). In EAM-RVAPS, a pacing map guided the implantation of ventricular leads in septal sites with narrower QRS. After implantation, LV contractility (ejection fraction [EF], Global Longitudinal Strain [GLS]) and synchrony were evaluated at 1-12 months. RESULTS: Twenty-one pediatric patients with CAVB, with (six patients) or without structural heart diseases, aged 4-16 (median 10.5) years, were divided in two groups: EAM-RVAPS (11 patients, four dual-chamber/DDD, seven single-chamber/VVIR pacemakers) and RVA (10 patients, one DDD/nine VVIR). The two groups did not show significant differences for preoperative parameters. EAM-RVAPS showed: preserved LVEF and synchrony (not significantly different than RVA), significantly lower GLS and radiation doses/exposures, in spite more complex procedures, significantly longer procedure times and narrower paced QRS than RVA. CONCLUSIONS: EAM-guided procedures have been useful to reduce radiation exposure and to localize RVAPS with narrower paced QRS and lower GLS than RVA.


Assuntos
Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Disfunção Ventricular Esquerda/prevenção & controle , Disfunção Ventricular Esquerda/fisiopatologia , Criança , Pré-Escolar , Feminino , Fluoroscopia , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
8.
Artigo em Inglês | MEDLINE | ID: mdl-29873818

RESUMO

AIM: Young patients with operated complex congenital heart defects (CHD) often develop sinus node dysfunction (SND) requiring permanent pacing with rate-responsive function. Activity-driven sensors cannot account for nonmovement stress and cannot modulate heart rate physiologically. Closed Loop Stimulation (CLS, Biotronik, Berlin, Germany) is a physiological rate-responsive pacemaker based on the indirect measure of ventricular contractility. No data are available on the effects of such pacing strategy in young patients. METHODS: We report a series of nine patients with CHD and SND who underwent single-chamber CLS-atrial pacing with endocardial or epicardial lead. During the first 30 days, the pacemaker was programmed in AAI pacing mode and then was switched to CLS-atrial pacing mode. An in-hospital control was scheduled 1-2 months later to evaluate the CLS response to neurovegetative stresses (i.e., nonmovement stress [Stroop color test, handgrip] and exercise stress test) and Holter monitor. CLS pacing was compared with rate-responsive accelerometer-driven pacing (AAIR). RESULTS: At telemetric interrogation, CLS pacing showed a more physiological pattern of 24-h heart rate trends than accelerometer sensors. The data obtained during nonmovement/exercise stress demonstrated a physiological increase in the pacing rate with CLS, in synergy with spontaneous events. The accelerometer sensor histogram, during nonmovement stress, showed a "nonresponse" behavior (only lower rate events), and during exercise test showed most events in lower rate range. Holter monitoring showed increase of average and maximum heart rate compared with AAIR. CONCLUSION: In young CHD patients, endocardial/epicardial CLS-atrial pacing demonstrated a physiological response of heart rate to neurovegetative and physical stresses.

9.
Europace ; 20(12): 1966-1973, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29939256

RESUMO

Aims: Use of the subcutaneous implantable cardioverter-defibrillator (S-ICD) to prevent sudden cardiac death is increasing. Few data exist on S-ICD in young patients. We reviewed our single-centre experience in order to assess the effectiveness and safety of S-ICD implantation, and to identify potential factors associated with complications. Methods and results: Observational, non-randomized, standard-of-care study on S-ICD implantation/follow-up in young patients with inherited arrhythmias (IA), cardiomyopathies, and congenital heart defects (CHD). Fifteen patients (6 CHD, 8 cardiomyopathies, and 1 IA), median age 15 years (25th-75th centiles, 14-28), 10 of them <18 years, with body mass index (BMI) 22.6 ± 3.4, underwent S-ICD implantation (primary prevention 93%). The first six patients underwent a standard implantation procedure (three surgical incisions), the following nine a two-incision procedure. No intraoperative complications occurred. Over 12 (7-24) months follow-up, two patients received appropriate shocks and one (7%) inappropriate shock. Four patients had device-related complications requiring surgical intervention: three skin erosions at the superior parasternal incision, one pocket infection. A higher risk of complications was seen in patients who underwent standard procedures [hazard ratio (HR) 4.98, 95% confidence interval (CI) 1.53-47.36; P = 0.0482] and those with BMI <20 (HR 9.44, 95% CI 0.95-93.23; P = 0.0169). Conclusion: S-ICD implantation was safe and effective in young patients with low rates of inappropriate shock. However, the risk of device-related complications during follow-up remains substantial in patients with low BMI. To prevent possible complications, a two-incision technique should be preferred.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Adolescente , Adulto , Fatores Etários , Índice de Massa Corporal , Criança , Tomada de Decisão Clínica , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Masculino , Seleção de Pacientes , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Cidade de Roma , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
10.
Pacing Clin Electrophysiol ; 40(9): 995-1003, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28744930

RESUMO

AIMS: Right ventricular (RV) apical (RVA) pacing can induce left ventricular (LV) dyssynchrony, remodeling, and dysfunction in children with complete atrioventricular block (CAVB). We compared the functional outcome of RVA with RV alternative pacing sites (RVAPS), including para-Hisian, septal, and outflow tract sites. METHODS: This is a single-center, retrospective study. Data were collected before pacemaker implantation (transvenous leads), postoperatively, at 6 months, and at 1-2-3-4 years. Electrocardiogram evaluation included QRS duration, axis, QTc/JTc, and QTc dispersion. Echocardiographic evaluation included 2-D/3-D assessment of ventricular dimensions (Z-score of LV end-diastolic dimension), function (ejection fraction), and synchrony. RESULTS: From 2009 to 2015, 55 patients with CAVB, aged 3-17 years, with or without other congenital heart defects, underwent RVAPS (30 patients, median age 11 years) or RVA (25 patients, median 12 years). All leads were positioned into the septum. Before implantation, no significant differences in parameters were observed, except for higher Z-score in RVAPS than in RVA. After implantation, at a median follow-up of 2.5 (range 1-6) years, the two groups showed no significant differences in LV dimensions, contractility, and synchrony. QRS intervals of RVAPS were significantly shorter than RVA. Clinical status was good and contractility/synchrony indexes were normal or adequate in all patients. CONCLUSIONS: In pediatric patients, RVAPS and RVA showed no significant differences in LV dimensions, contractility, and synchrony. Preimplantation dilated patients showed LV reverse remodeling. RVAPS demonstrated shorter QRS intervals. Therefore, septal pacing sites, either RVA or RVAPS, seem to determine good contractility and synchrony at a mid-term follow-up.


Assuntos
Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Endocárdio/fisiologia , Contração Miocárdica , Marca-Passo Artificial , Adolescente , Criança , Pré-Escolar , Feminino , Ventrículos do Coração , Humanos , Masculino , Implantação de Prótese , Estudos Retrospectivos , Resultado do Tratamento
11.
Europace ; 19(7): 1198-1203, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28201731

RESUMO

Introduction: Advances in 3D electroanatomic-mapping technologies have resulted in a safe and effective profile of radiofrequency (RF) catheter ablation. The aim of this study was to evaluate a different catheter ablation approach in patients with left-sided accessory pathways (APs). Methods and results: From January 2015 to December 2015, 30 patients (median age 11 years, median weight 45 kg) with manifest or concealed left-sided APs underwent RF catheter ablation with a new protocol. All procedures were performed with the CARTO UNIVU™ system, integrating electroanatomic maps with fluoroscopic views. A 7 Fr ablation catheter was inserted into the right femoral vein and advanced into the right atrium. Geometrical reconstruction and activation map of the right atrium, tricuspid annulus, and coronary sinus were acquired. The ablation catheter was then inserted into the left femoral artery and advanced through the aorta and aortic valve, creating an activation map of the mitral annulus. Catheter ablation was targeted to the site of the earliest activation. No complications occurred. The median procedure and fluoroscopy times were 130 min and 6 s, with a median fluoroscopy dose 0.5 mGy. An average of two catheters was used. Long-term success rate was 97% (29/30) at a median follow-up of 9.6 months. This approach reduced fluoroscopy time, dose and number of catheters used compared with manifest or concealed left-sided AP ablation using CARTO 3™ (P < 0.05). Conclusions: This new ablation protocol seems to be promising in reducing fluoroscopy exposure and number of catheters used during left-sided AP ablation in children.


Assuntos
Feixe Acessório Atrioventricular , Arritmias Cardíacas/cirurgia , Técnicas Eletrofisiológicas Cardíacas/métodos , Radiografia Intervencionista/métodos , Potenciais de Ação , Adolescente , Fatores Etários , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Criança , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Feminino , Fluoroscopia , Frequência Cardíaca , Humanos , Masculino , Duração da Cirurgia , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
12.
Pacing Clin Electrophysiol ; 39(11): 1198-1205, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27716977

RESUMO

BACKGROUND: Transcatheter cryoablation is a well-established technique for the treatment of atrioventricular nodal reentry tachycardia (AVNRT) in children. Nevertheless, atrioventricular nodal slow-pathway conduction may recur after an acutely successful procedure. The aim of this study was to evaluate the long-term outcome of acutely successful AVNRT cryoablations in pediatric patients in case of focal cryolesion and in case of need for High-Density Linear Lesion (HDLL) cryoablation due to focal failure. METHODS: Sixty-nine consecutive pediatric patients (30 males, mean age 12.4 ± 3.2 years; range: 5.4-18.0 years) underwent 3D-guided cryoablation for AVNRT at our institution from July 2013 to November 2014. When a focal cryoablation was acutely unsuccessful, a 3D-guided HDLL was created delivering multiple overlapping cryolesions/cryoenergy applications from the ventricular side of the tricuspid annulus to the atrial side, including the site of focal cryoablation if transiently successful. RESULTS: No permanent cryoablation-related complications occurred. Acute success rate was 98.5% (68 out of 69): in 55.9% (38 out of 68) with focal-lesion and in 44.1% (30 out of 68) with HDLL. Mean follow-up was 25.3 months and AVNRT recurrence rate was 13.2% (nine out of 68): 5.2% (two out of 38) with focal lesion and 23.3% (seven out of 30) with HDLL (P = 0.036). CONCLUSIONS: In cryoablation of AVNRT in children, the need for a more aggressive protocol (HDLL), due to the failure of focal ablation, is strictly related to higher recurrence rates. Indeed, AVNRT recurrences after cryoablation in children seem to be due to a larger and deeper substrate rather than due to the type of energy used.


Assuntos
Criocirurgia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , Criança , Pré-Escolar , Criocirurgia/métodos , Feminino , Seguimentos , Humanos , Masculino , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...